Description of drop code

Antrax - –°onsultation on system performance

Description of drop code

All calls with such errors end with 42 code
LIMIT_FAS_ATTEMPTS - error of exceeding the FAS limit when trying to call;
INVALID_CALLER_FILTER - error that means that the call filter is not configured properly, that is, the correct setting of the A number;
INVALID_CALLED_FILTER - error that means that the call filter is not configured correctly, that is, the dialing is wrong;
ANSWER_ERROR - error in lifting the handset on the module. The error in the log itself:
logger.warn("[{}] - can't answer for incoming call", callChannel, e)
START_AUDIO_PROBLEM - error of opening the audio channel on the module. The error itself in the logs For the incoming:
logger.warn("[{}] - can't start incoming call", callChannel, e)
For outgoing:
logger.warn("[{}] - can't process terminating call [{}]", this, terminatingCall, e)
ORIGINATING_ERROR - error of the beginning of the call in the VoIP network. The error in the log itself:
logger.info("[{}] - can't start new call for incoming call", callChannel)
TERMINATING_ERROR - dialing error on the module or end of the outgoing call due to the busy module by another call. The error in the log itself:
logger.error("[{}] - can't process terminating call [{}], because another call is active", this, terminatingCall);
logger.warn("[{}] - can't process terminating call [{}]", this, terminatingCall, e);


 